American Standard Heat Pump ADD

Sometimes everything just goes real smooth, this was one of those jobs.

This customer belongs to a local church where several American Standard furnaces, heat pump and a Navien tankless heater where installed. He liked what was done for the church and wanted an air conditioner installed for him as well. Of coarse anyone asking for AC will more than likely switch to a HP once they see the benefits.

Existing Furnace

Existing Furnace

He kept the existing Trane furnace because its not that old and has plenty of blower power for a American Standard heat pump add on. In most add on cases you simply remove the old furnace, install the coil and re-install the existing furnace.

New American Standard Coil

New American Standard Coil

Here you see the new American Standard cased coil installed under the existing furnace and a new Honeywell F100 filter bank installed in the return air above it. Once the coil is installed a refer line set is ran from the indoor coil to the outdoor heat pump followed by a drain line.

New American Standard heat pump

New American Standard heat pump

The American Standard 13 Seer Heat Pump installed next to the garage, I have never seen a home or business that its colors does not match the American Standards heat pump.

Heating And Cooling Skagit County

Need a Heat Pump, Air Conditioner, Furnace, Boiler or Tankless Water Heater? We install them all over Skagit county including Mount Vernon WA, Burlington WA, Anacortes, Sedro Woolley, La Conner, Stanwood WA, and on Camano Is.

(2) American Standard 95% 2 Stage Variable

There are certain types of projects that really appeal to me, these projects generally have the biggest impact or affect for the customer and are usually the most challenging. This project was for the Church Of Christ in Mount Vernon, their oil furnace was from 1951 and it was a monster. Time for a upgrade!

Existing Oil Furnace

Existing Oil Furnace

The furnace was located in the basement in a room about 9′ by 9′ and it consumed most of that room. I had to stand back out of the room just to take a good picture(above). One of the biggest challenges with small community Church’s is the furnace sizing. A lot of small Church’s only get occupied say 1 to 2 times per week and the rest of the time the furnace generally stays off. So you have to consider raising the temperature say from 50 degrees to 70 degrees just for a few hours, and within a short period of time. And of coarse keeping the noise level down. Perfect for the American Standard 95% 2 Stage Variable.

New American Standard 95% 2 stage Variable

New American Standard 95% 2 stage Variable

One of the complaints from the church was the down stairs is always cold, and even though they had damper controls to help with this issue it never seemed to work correctly, therefore they abandoned that part of the system and went to space heaters. The American Standard 95% Variable 2 Stage furnace with a Honeywell 4″ pleated filter system (above) was installed to deal with just the down stairs, fortunately the existing duct work was zoned to do just that. As you can see the foot print is much smaller than the oil furnace.

Attic Ducting.

Attic Ducting.

Now for upstairs I decided to move the furnace location to the attic, as you can see in the picture above there was plenty of room. This of coarse required some duct modifications.

New American Standard 95% 2 stage Variable

New American Standard 95% 2 stage Variable

The new American Standard 95% Variable 2 stage furnace and Honeywell 4″ Filter installed like a dream. I had to convert some of the ducting to return while keeping the rest supply air. I also installed a Heat Pump, seeing how they wanted air conditioning I convinced them a Heat Pump is the way to go for added cost savings. As you can see I installed an emergency drain pan under the unit just in case we have a leak. The LP tank you see is for temporary back up heat until we get gas to the building.

New American Standard Heat Pump

New American Standard Heat Pump

Here is the new American Standard Heat Pump, funny how they always seem to match the building color. The refer pipe had to be installed on the exterior of the building and travel up to the attic, so we used a gutter pipe to conceal this piping. Works very well.

New Honeywell Thermostats

New Honeywell Thermostats

And to control the 2 furnaces we installed 1 Honeywell VisionIAQ and a 1 Honeywell VisionPRO 8000. Both the thermostats where located in the mechanical room and both where installed with remote sensors in the occupied spaces. By using remote sensors no unauthorized fingers can adjust the temperature.

 

Need a Heat Pump, Air Conditioner, Furnace, Boiler or Tankless Water Heater? I install them all over Skagit county including Mount Vernon WA, Burlington WA, Anacortes, Sedro Woolley, La Conner, Stanwood WA, and on Camano Is.

Carrier To American Standard

This heat Pump was kinda a head scratcher for me, not because the Carrier Heat Pump we replaced was only 10 years old, but the company that put this in is usually very customer orientated and for some reason let this one fall to the way side. The customer had been having issues with the system since day 1, and for some reason this company could not fix the problem. Maybe the technicians that had been coming out every year after year trying to remedy the problem did not understand air flow …or maybe the head office did not want the burden of dealing with the real problem. Never the less they lost a customer!

Existing Carrier Air Handler

Existing Carrier Air Handler

I must apologize for the picture above, I forgot my camera so I must resort to a picture my technician took when we he was called out. Everything he found on the system suggested they where trying workarounds, meaning not dealing with the real issue. The real issue being lack of airflow, the system could not deliver the air needed for the heat pump.

New American Standard Heat Pump

New American Standard Heat Pump

The solution above, an American Standard variable speed air handler. Even though the existing air handler was rated for the job, it could not push the air needed through the existing ducting. BUT this air handler is designed to do just that.

New American Standard Heat Pump

New American Standard Heat Pump

The American Standard heat Pump above is a perfect match for the indoor handler and existing home. The existing refer lines where flushed clean to switch over to the R410a refrigerant.

Alpine Heating And Cooling Vans

Alpine Heating And Cooling Vans

Later in the day the sun hit my vans just perfect for a picture. After all it was a perfect day, I gained a happy customer, the customer got a quality matched system with no air flow issues and I got home on time 🙂

 